Select options
This product has multiple variants. The options may be chosen on the product page
SLVR® Scrubs - SLVR777™ fabric (report DZ2025A082)
The SLVR777™ fabric used in SLVR® Scrubs was tested by a CNAS-accredited (ISO/IEC 17025) laboratory, Beijing Daze Technology (report DZ2025A082, October 2025). Result: 30.7 dB (99.91%) signal attenuation at 50 GHz through a single layer of fabric, and 35.2 dB (99.97%) or more at every test point from 30 MHz to 40 GHz. Results are for the fabric sample tested. Whole-garment performance is lower at openings and seams. Designed to reduce RF signal exposure. Not a medical device.
15 frequencies (16 measurements) from 9 kHz to 50 GHz
Measured using GJB 5792A-2021, a Chinese military-standard (GJB) shielding measurement method.
Download SLVR® Scrubs SLVR777™ Lab Report DZ2025A082 (PDF)
| Measured frequency | Measured point | Number of test points | Unshielded spatial signal (dBμV) | Signal inside shielded room (dBμV) | Shielding effectiveness (dB) | Shielding effectiveness, linear representation (%) |
|---|---|---|---|---|---|---|
| 9 kHz | Mid Point | 1 | 97.0 | 96.0 | 1.0 | 20.5672 |
| 150 kHz | Mid Point | 1 | 103.0 | 101.7 | 1.3 | 25.8690 |
| 15 MHz | Mid Point | 1 | 96.6 | 70.7 | 25.9 | 99.7430 |
| 30 MHz | Mid Point | 1 | 100.0 | 46.5 | 53.5 | 99.9996 |
| 100 MHz | Mid Point | 1 | 104.0 | 51.0 | 53.0 | 99.9995 |
| 450 MHz | Mid Point | 1 | 106.7 | 63.0 | 43.7 | 99.9957 |
| 950 MHz | Mid Point | 1 | 103.5 | 61.0 | 42.5 | 99.9944 |
| 1500 MHz | Mid Point | 1 | 116.0 | 76.0 | 40.0 | 99.9900 |
| 3 GHz | Mid Point | 1 | 109.0 | 62.0 | 47.0 | 99.9980 |
| 6 GHz | Mid Point | 1 | 98.0 | 51.3 | 46.7 | 99.9979 |
| 10 GHz | Mid Point | 1 | 106.5 | 58.1 | 48.4 | 99.9986 |
| 18 GHz | Mid Point | 1 | 107.5 | 63.5 | 44.0 | 99.9960 |
| 26 GHz | Mid Point | 1 | 107.2 | 67.8 | 39.4 | 99.9885 |
| 40 GHz | Mid Point | 1 | 99.7 | 64.5 | 35.2 | 99.9698 |
| 50 GHz | Mid Point of One Layer Shielding Material | 1 | 95.7 | 65.0 | 30.7 | 99.9149 |
| 50 GHz | Mid Point of Two Layers Shielding Material | 1 | 95.7 | 42.0 | 53.7 | 99.9996 |
Shielding Effectiveness = Unshielded Spatial Signal − Signal inside Shielded Room.
Other products
Hat, Faraday phone pouch, beanie, polo, Large and X-Large blankets
Lab testing of this product's shielding fabric is in progress. Results will be posted on our Lab Results page when complete.
Testing in progress
Baby blanket: No shielding claim made
MRI note: Silver fibers are conductive. Remove before entering the MRI scanner room.