Lab Results by Product

SLVR® Scrubs - SLVR777™ fabric (report DZ2025A082)

The SLVR777™ fabric used in SLVR® Scrubs was tested by a CNAS-accredited (ISO/IEC 17025) laboratory, Beijing Daze Technology (report DZ2025A082, October 2025). Result: 30.7 dB (99.91%) signal attenuation at 50 GHz through a single layer of fabric, and 35.2 dB (99.97%) or more at every test point from 30 MHz to 40 GHz. Results are for the fabric sample tested. Whole-garment performance is lower at openings and seams. Designed to reduce RF signal exposure. Not a medical device.

15 frequencies (16 measurements) from 9 kHz to 50 GHz

Measured using GJB 5792A-2021, a Chinese military-standard (GJB) shielding measurement method.

Download SLVR® Scrubs SLVR777™ Lab Report DZ2025A082 (PDF)

Shielding effectiveness — report DZ2025A082, page 5. Test conditions: 22°C, 40% RH.
Measured frequencyMeasured pointNumber of test pointsUnshielded spatial signal (dBμV)Signal inside shielded room (dBμV)Shielding effectiveness (dB)Shielding effectiveness, linear representation (%)
9 kHzMid Point197.096.01.020.5672
150 kHzMid Point1103.0101.71.325.8690
15 MHzMid Point196.670.725.999.7430
30 MHzMid Point1100.046.553.599.9996
100 MHzMid Point1104.051.053.099.9995
450 MHzMid Point1106.763.043.799.9957
950 MHzMid Point1103.561.042.599.9944
1500 MHzMid Point1116.076.040.099.9900
3 GHzMid Point1109.062.047.099.9980
6 GHzMid Point198.051.346.799.9979
10 GHzMid Point1106.558.148.499.9986
18 GHzMid Point1107.563.544.099.9960
26 GHzMid Point1107.267.839.499.9885
40 GHzMid Point199.764.535.299.9698
50 GHzMid Point of One Layer Shielding Material195.765.030.799.9149
50 GHzMid Point of Two Layers Shielding Material195.742.053.799.9996

Shielding Effectiveness = Unshielded Spatial Signal − Signal inside Shielded Room.

Other products

Hat, Faraday phone pouch, beanie, polo, Large and X-Large blankets

Lab testing of this product's shielding fabric is in progress. Results will be posted on our Lab Results page when complete.

Testing in progress

Baby blanket: No shielding claim made

MRI note: Silver fibers are conductive. Remove before entering the MRI scanner room.